| Environment Specifications |
| Operating |
| Temperature |
16° to 32°C (60° to 90°F) |
| Humidity |
20% to 80% |
| Wet Bulb |
25.6°C (78°F) |
| Altitude |
0 to 3.05 km (0 to 10,000 ft.) |
| Storage |
| Temperature |
4.4° to 32°C (40° to 90°F) |
| Humidity |
10% to 90% |
| Wet Bulb |
26.7°C (80°F) |
| Altitude |
0 to 3.05 km (0 to 10,000 ft.) |
| Transit |
| Temperature |
-10°C to 48°C (-23°F to 120°F) |
| Humidity |
5% to 100% |
| Wet Bulb |
26.7°C (80°F) |
| Altitude |
0 to 15.24 km (0 to 50,000 ft.) |
NOTE:
The shipping environment must not exceed the limits of the storage environment for a period longer than 10 days. |
| Power Requirements |
| 50/60Hz (200-240 VAC Nominal) |
Single Phase, 3 Wire |
| Operating Power Consumption (4 CTUs, 4 CSLs, 1 SSU) |
1.67 kVA (1.56 kW) |
| Operating Line Frequencies |
Between 47 and 63 Hz Delta Connection |
| Operating Heat Output (4 CTUs, 4 CSLs, 1 SSU) |
1,340 kcal/hr. (5,300 Btu/hr.) |
| Power Connectors |
Russell Stoll 3720 |
| U.S./Canada |
IEC 309 Type |
| Line Voltage |
200 |
208 |
220 |
230 |
240 |
| Tolerance |
+/-10 |
+10 / -15 |
+10 / -15 |
+/-10 |
+10 / -15 |
| Phases |
1 |
1 |
1 |
1 |
1 |
| Maximum Amps RMS |
9.2 |
9.2 |
9.2 |
9.2 |
9.2 |
|
|
|
|
|
|